Question: Control panel display Err2 or drainage failure

Answer:

 Reason 1.Drain hose end is higher than 100 cm above the floor level.

Solution 1.Make sure the drain hose end is between 80-100 cm above floor level.

 

Reason 2.The filter is blocked.

Solution 2.Clean the filter once a month: If you don’t clean it usually, the drain pump will not pump out water  due to clogged , perhaps will display Err2.

1.Pull out the bottom cover with thin objects to tools carefully.

2.Pull the drain hose out of the sewage set in the bottom panel. Hold the drain hose into a water container, take out the plastic plug and let the excess water flow into the container. Reinstall the plug and push the hose back.

3.Remove the filter by turning counterclockwise.

4.Fluse the filter clean with running water.

5.Replace the filter by turning clockwise and remount the cover.

 

Reason 3.Drain hose is blocked.

Solution 3.Clean the drain hose for blockage.

Related Models:
HWBD60-B1209G HWB60-B1209G HW50-1010 HW50-1010A HWD60-1403D HW70-1479 HWD80-1482 HW80-B14266A HW80-1479 HW100-1479N HW80-B14266
Content Feedback
* 1. Is this content useful ?
* 2. Please evaluate this content ?

3. Please give us some suggestion.

SUBMIT
Product guide

Need your product manual or software? You can find them here!
Repair request registration

One step,our door to door service standby.

DR. FIDO Live Chat


Your online customer care expert. Get your queries answered instantly.

9.00 AM to 9.00 PM
(Monday to Saturday)

Ask a question


Submit a question to our support team

Start now

Toll Free Hotline Number


0333 003 8122

0344 561 1234

Contact us


Submit a question to our support team

Start now

Hotline


0333 003 8122

0344 561 1234

European Hotlines