Home Commercial Air Conditioners AD132HC1QRA / 1U132WC1QRB
  • Features
  • Specifications
  • Manual
  • 11.0-TR-Duct-IDU
  • 11.0-TR-Duct-ODU
  • YR-E17
  • YR-E16B
    • 11.0-TR-Duct-IDU
    • 11.0-TR-Duct-ODU
    • YR-E17
    • YR-E16B
    11.0-TR-Duct-IDU

    11 TR Inverter - Cooling Only Duct AC

    AD132HC1QRA / 1U132WC1QRB

    • ESP up to 220 Pa
      ESP up to 220 Pa
    • 4-Rows Wide-Fin Heat Exchanger
      4-Rows Wide-Fin Heat Exchanger
    • 3-Ph Sequence Correction Technology
      3-Ph Sequence Correction Technology
    MRP
    : ₹
    275134
    In store stocks availability are subject to respective retailers.
    • Capacity
      11 TR
    • Power Supply
      3Ph/380-415V/50Hz
    • Working Temperature
      60⁰C
    • Refrigerant
      R-410a
      Comfort
      Haier Ductable Range of ACs are having Multiple Air Flow Choice - 5 Speed. This makes the System Super Efficient.
      Ductable Multiple Airflow Choice
      Design Superiority
      Haier Ductable Indoor Units having 4-Rows & Wide-Fin Heat Exchanger, which can reduce more Humidity than 2 or 3 row Heat Exchanger in Traditional Duct Unit.
      Ductable 4 Row Deep Heat Exchanger in Indoor Unit
      Long Distance Ducting
      Design Flexibility is wide with Haier Ductable Range of ACs. This is possible due to Superior Grade of Fan Motor and Blower Design used in these machines.

      Ducting - Long Distance
      Long Distance Piping
      Flexibility in Indoor and Outdoor Location. Superior Design of Haier Ductable Range of ACs make this a possibility.

      LDP 11 TR
      Multiple ESP Setting Choice
      Haier Ductable Range of ACs are equipped with Multiple ESP Setting Choice upto 10 Steps. The ESP can reach upto 220 Pa. This provides a lot of Flexibility for Duct Design. Even a wrongly Designed Duct can be synchronised with Haier Ductable Range of ACs by ESP Setting option, which can be done by Wired Controller. Very useful for Retrofit Projects.
      Ductable ESP Setting
      Controller Option
      Haier Ductable Range of ACs can be connected with various type of Controllers as per need. Option of choosing from Individual, Group or Central Controller.
      Controller Image
      3-Ph Sequence Correction Technology
      The Air-conditioner works all the time, even if Phase Sequences Changes.
      Automatic Phase Sequence Corrector
      Outdoor Features
       DC Inverter Compressor: Better Part Load Efficiency.  
       550 mm Larger Diameter Fan: Increased Efficiency, Lower  
         Noise Level of 48 dB(A).
       Better Fin Design: 18.8 mm Depth Corrugation Fin  
         resulting in Less Dust Accumulation and better Heat 
         Transfer.  
       Hyper PCB with Protection Coating, Insect Proof, Water 
         Proof, suitable for Hot & Humid Environment.  
       Upto 60⁰C Operation.  
       Health Check and Maintenance possible through 
         Computer/ Software connected to PCB Port.
      2 Fan Outdoor

      Similar Products

      4.0 TR Fixed Speed - Cooling Only Tower AC

      AP48KC1QRA / 1U48NC1QAB

      • Capacity 3Ph/380-415V/50Hz
      • Power Supply 4.0 TR
      • Working Temperature 600 x 350 x 1850
      • Refrigerant R-410a
      More

      4.0 TR Inverter - Heat Pump Tower AC

      AP48KC1ERA / 1U48IC2ERB

      • Capacity 3Ph/380-415V/50Hz
      • Power Supply 4.0 TR
      • Working Temperature 600 x 350 x 1850
      • Refrigerant R-410a
      More

      3.0 TR Inverter - Heat Pump Tower AC

      AP36KC1ERA / 1U36HC1ERA

      • Capacity 1Ph/220-240V/50Hz
      • Power Supply 3.0 TR
      • Working Temperature 600 x 350 x 1850
      • Refrigerant R-410a
      More

      My Tracks

      {"GROUP":[{"Field":[{"Capacity":"11.0 TR / 132000 BTU / 38.67 KW"},{"ISEER":"3.5"},{"Type":"Light Commercial"},{"Price":"275134"}],"name":"Specification"},{"Field":[{"Air Flow (H/M/L) - CFM":"4400/4000/3588"},{"ESP - Pa":"10-220"},{"Sound Pressure Level (H/M/L) - dB(A)":"53/50/47"},{"IDU Dimension (W/D/H) - mm":"1330/895/500"},{"IDU Net Weight - Kg":"99"},{"Evaporator Coil":"4 Row Deep Wide-Fin"}],"name":"Indoor Unit Specification"},{"Field":[{"Power Supply":"3-Ph/380-415V/50Hz"},{"Air Flow - CFM":"5882"},{"Sound Pressure Level - dB(A)":"65"},{"ODU Dimension (W/D/H) - mm":"1050/400/1636"},{"ODU Net Weight - Kg":"160"},{"Refrigerant Type":"R-410a"},{"Liquid Pipe Size - mm":"12.7"},{"Gas Pipe Size - mm":"22.2"},{"Total Pipe Length - m":"70"},{"Max. Pipe Length - Horizontal - m":"50"},{"Max. Pipe Length - Vertical - m":"20"},{"Operation Temp. - ℃":"18~60"}],"name":"Outdoor Unit Specification"}]}

      User Guides

      File Name 11.0 TR Inverter Duct - AC
      Update Date 2020-07-23
      File Size 182.2KB
      Download
      Disclaimer: Design, features and specifications are subject to changes without prior notice.

      Not able to find what you're looking for? We're here to help.